QD series introduction:This chamber is suitable for the product (complete machine), parts, materials to perform high temperature test, low temperature test, altitude(no higher than 30000m or 45000m ) test, high&low temperature cycling test and temperature-altitude integrated test. When performing high&low temperature test, this chamber can be used for the tests of heat emission samples and non heat emission samples. For the test of heat emission samples, the cooling power can not exceed the refrigeration capacity of chamber, because the refrigeration capacity is a dynamic value, which will change with changeable temperature.
QD series technical parameters
Type | QD6025 | QD605 | QD61 | QD62 | ||
Performance parameters |
Temperature range | -70~+150℃ | ||||
Temperature fluctuation | ±0.5℃(normal pressure and no load) | |||||
Temperature uniformity | ≤2℃(normal pressure and no load) | |||||
Temperature deviation | ±2℃(normal pressure and no load) | |||||
Heating up time(20~+150℃) | ≤60min | ≤60min | ≤50min | ≤60min | ||
Cooling down time(20~-60℃) | ≤90min | ≤80min | ≤60min | ≤80min | ||
Air pressure range | normal pressure~1KPa | normal pressure~0.5KPa | ||||
Pressure precision | ±2KPa(at normal pressure ~40KPa);±5%(at 40KPa~4KPa);±0.1KPa(at 4KPa~1KPa) | |||||
depressurization rate | ≤45min(normal pressure →1KPa) | |||||
Structure | Shell | Cold-rolled steel plate with surface spray(ivory) | ||||
Inner wall material |
Stainless steel plate |
|||||
Refrigeration | Refrigerating method | Water cooling | ||||
Refrigerator | Imported compressor | |||||
Observation window(mm) | 200×300mm (W×H) | |||||
Temperature sensor | Armoured Pt100 | |||||
Pressure sensor | Silicon resistance pressure transmitter | |||||
Controller | Siemens PLC module and 7-inch color LCD touch control screen. | |||||
Data storage and interfaces | SD data card, USB, RS485 | |||||
Inner dimension (mm) |
D | 600 | 700 | 1000 | 1200 | |
W | 600 | 800 | 1000 | 1400 | ||
H | 700 | 900 | 1000 | 1200 | ||
External dimension (mm) |
D | 1800 | 2750 | 3250 | 3710 | |
W* | 1000 | 1500 | 1400 | 1810 | ||
H | 1880 | 1900 | 2000 | 2310 | ||
Installed power | 19KVA | 19.3KVA | 32.5KVA | 51KVA | ||
Power supply | AC380V 50Hz three phase four wire + ground wire | |||||
Standard configuration | 1 product operation manual, 1 test report, 1 certification, 1 quality certificate, 2 shelves and 4 racks | |||||
Satisfy the standards | GJB 150.2、GJB 150.3、GJB 150.4、GJB 150.6、GB/T 2423.1、GB/T 2423.2、GB/T 2423.21 |